3. Basic operation
The S-5716 Series changes the output voltage level (VOUT) according to the level of the magnetic flux density (N pole
or S pole) applied by a magnet.
The following explains the operation when the magnetism detection logic is active "L".
3. 1 Product with both poles detection
When the magnetic flux density vertical to the marking surface exceeds the operation point (BOPN or BOPS) after the
S pole or N pole of a magnet is moved closer to the marking surface of the S-5716 Series, VOUT changes from "H"
to "L". When the S pole or N pole of a magnet is moved further away from the marking surface of the S-5716
Series and the magnetic flux density is lower than the release point (BRPN or BRPS), VOUT changes from "L" to "H".
Figure 16 shows the relationship between the magnetic flux density and VOUT.
BHYSN
VOUT
BHYSS
H
N pole
BOPN
BRPN
0
BRPS
Magnetic flux density (B)
BOPS
L
S pole
Figure 16
3. 2 Product with S pole detection
When the magnetic flux density vertical to the marking surface exceeds BOPS after the S pole of a magnet is moved
closer to the marking surface of the S-5716 Series, VOUT changes from "H" to "L". When the S pole of a magnet is
moved further away from the marking surface of the S-5716 Series and the magnetic flux density is lower than
BRPS, VOUT changes from "L" to "H".
Figure 17 shows the relationship between the magnetic flux density and VOUT.
VOUT
BHYSS
H
N pole
0
BRPS
Magnetic flux density (B)
BOPS
Figure 17
L
S pole
16