English
Language : 

S-19190AOH-M6T1U Datasheet, PDF (14/24 Pages) Seiko Instruments Inc – VOLTAGE MONITORING IC WITH CELL BALANCING FUNCTION
FOR AUTOMOTIVE 105°C OPERATION VOLTAGE MONITORING IC WITH CELL BALANCING FUNCTION
S-19190 Series
Rev.1.3_00
3. Overcharge status
In the S-19190 Series, if VDS is the overcharge detection voltage (VCU) or higher and this status continues for
the overcharge detection delay time (tCU) or longer, the CO pin output is inverted. The CO pin output status
varies according to the output form and output logic selected, as shown in Table 12. This is the overcharge
status. In the overcharge status, the CB pin output becomes "L".
Table 12
CO Pin Output Form and Output Logic CB Pin Output CO Pin Output
CMOS output, active "H"
"L"
"H"
CMOS output, active "L"
"L"
"L"
Nch open-drain output, active "H"
"L"
"H"
Nch open-drain output, active "L"
"L"
"L"
The overcharge status is released when VDS drops to the overcharge release voltage (VCL) or lower and this
status continues for the overcharge release delay time (tCL) or longer.
_____
4. CE pin
_____
The S-19190 Series has the CE pin (Power-saving mode switc__h__i_ng pin). The S-19190 Series is set to
power-saving
mode
by
inputting
a
voltage
of
V_____
CEH
or
higher
to
the
CE
pin.
_____
CE Pin
Open
(V_____
CE
=
VSS)
"H" (V ≥ V ) _____
CE
_____
CEH
"L" (V ≤ V ) _____
CE
_____
CEL
Table 13
Status
Normal operation mode
Power-saving mode
Normal operation mode
In power-saving mode, the current consumption is decreased to current consumption during power-saving (IPSV).
The CB pin or the CO pin output in power-saving mode is the same as that in the normal status.
_____
The__C__E_ pin is pulled down to VSS by the internal resistor. When in a mode other than power-saving mode, leave
the CE pin open or short it with VSS.
14