4. 3 Erasing data (ERASE)
To erase 16-bit data at a specified address, set all 16 bits of the data to "1", change the CS pin to "H", and then
input the ERASE instruction and address following the start bit. There is no need to input data. The data erase
operation starts when the CS pin goes to "L". When the clocks more than the specified number have been input,
the clock pulse monitoring circuit cancels the ERASE instruction. For details of the clock pulse monitoring circuit,
refer to " Function to Protect Against Write due to Erroneous Instruction Recognition".
tCDS
CS
Verify
Standby
SK
1 2 34 5 67 8 9
DI
<1> 1 1 A5 A4 A3 A2 A1
A0
High-Z
DO
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 6 Data Erase Timing (S-93S46A)
CS
tCDS
Verify
Standby
SK
1 2 3 4 5 6 7 8 9 10 11
DI
<1> 1 1
A6 A5 A4 A3 A2 A1 A0
DO
High-Z
x:S-93S56A
A7:S-93S66A
tSV
busy
ready
tHZ1
tPR
High-Z
Figure 7 Data Erase Timing (S-93S56A/66A)
Seiko Instruments Inc.