English
Language : 

S93C76A Datasheet, PDF (12/28 Pages) Seiko Instruments Inc – FOR AUTOMOTIVE 105C OPERATION
FOR AUTOMOTIVE 105°C OPERATION 3-WIRE SERIAL E2PROM
S-93C76A H Series
Rev.3.1_00
2. 3 Writing to chip (WRAL)
This instruction is used to write the same 16-bit data to the entire address space of the memory.
After making CS “H”, input a start bit, the WRAL instruction, an address, and 16-bit data. Any address may be
input. If data of more than 16 bits is input, the written data is sequentially shifted at each clock, and the 16-bit
data input last is the valid data. The write operation is started when CS is made “L”. It is not necessary to
set the data to “1” before it is written.
tCDS
CS
Verify
Standby
SK
1 2 3 4 5 6 7 8 9 10 11 12 13 14
29
DI
<1> 0 0 0 1
DO
High-Z
8Xs
D15
D0
tSV
tHZ1
busy ready
tPR
High-Z
Figure 9 Chip Write Timing
2. 4 Erasing chip (ERAL)
This instruction is used to erase the data of the entire address space of the memory.
All the data is “1”. After making CS “H”, input a start bit, the ERAL instruction, and an address. Any address
may be input. It is not necessary to input data. The chip erase operation is started when CS is made “L”.
tCDS
CS
Standby
Verify
SK
1 2 3 4 5 6 7 8 9 10 11 12 13
DI
<1> 0 0 1 0
8Xs
DO
High-Z
tSV
tHZ1
busy ready
tPR
High-Z
Figure 10 Chip Erase Timing
12