23. 0 V battery charge starting charger voltage (0 V battery charge function "available")
(Test circuit 2)
The 0 V battery charge starting charger voltage (V0CHA) is defined as absolute value of the voltage V2 at which VCO
goes to "H" (VCO = VDD) when the voltage V2 is gradually decreased under the set condition of V1 = V2 = V5 = 0 V.
24. 0 V battery charge inhibition battery voltage (0 V battery charge function "unavailable")
(Test circuit 2)
The 0 V battery charge inhibition battery voltage (V0INH) is defined as the voltage V1 at which VCO goes to "H" (VCO
= VDD) when the voltage V1 is gradually increased under the set conditions of V1 = V5 = 0 V, V2 = −2.0 V.