English
Language : 

S93C86B Datasheet, PDF (11/28 Pages) Seiko Instruments Inc – FOR AUTOMOTIVE 105C OPERATION
Rev.2.1_00
FOR AUTOMOTIVE 105°C OPERATION 3-WIRE SERIAL E2PROM
S-93C86B H Series
3. Reading (READ)
The READ instruction reads data from a specified address.
After CS has gone high, input an instruction in the order of the start bit, read instruction, and address. Since the last
input address (A0) has been latched, the output status of the DO pin changes from high impedance (High-Z) to low,
which is held until the next rise of SK. 16-bit data starts to be output in synchronization with the next rise of SK.
3.1 Sequential read
After the 16-bit data at the specified address has been output, inputting SK while CS is high automatically
increments the address, and causes the 16-bit data at the next address to be output sequentially. The above
method makes it possible to read the data in the whole memory space. The last address (A9  A1 A0 = 1 
1 1) rolls over to the top address (A9  A1 A0 = 0  0 0).
CS
SK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
26 27 28 29 30 31
42 43 44 45 46 47
DI
DO
<1> 1 0 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
High-Z
0 D15 D14 D13
D2 D1 D0 D15 D14 D13
D2 D1 D0 D15 D14 D13
High-Z
ADRINC
Figure 5 Read Timing
ADRINC
Seiko Instruments Inc.
11