English
Language : 

S-8235AAA-TCT1U Datasheet, PDF (11/24 Pages) Seiko Instruments Inc – FOR AUTOMOTIVE BATTERY PROTECTION IC
FOR AUTOMOTIVE BATTERY PROTECTION IC FOR 3-SERIAL TO 5-SERIAL CELL PACK (SECONDARY PROTECTION)
Rev.1.7_00
S-8235A Series
3. Overcharge timer reset function
The S-8235A Series has an overcharge timer reset function.
If overcharge release noise which temporarily falls below overcharge detection voltage n (VCUn) is input during
overcharge detection delay time (tCU) from when the voltage of one of the batteries during a charging operation exceeds
VCUn until when charging is stopped, tCU is continuously counted if the time of overcharge release noise is shorter than
overcharge timer reset delay time (tTR). On the other hand, under the same status, if the time of overcharge release
noise is tTR or longer, counting of tCU is reset once. After that, when VCUn is exceeded, counting tCU resumes.
VHCn
tTR or
shorter
tTR or
longer
tTR or
shorter
VCUn
Battery voltage
(n = 1 to 5)
CO pin
tCU or
shorter
tTR
Timer reset
tCU
Figure 6 Overcharge Timer Reset Operation
4. Status of pins
The status of pins for the S-8235A Series is shown in Table 6.
When inputting "H" to the CTL pin, the CO pin outputs "H" in 1.0 ms typ. at normal status, and maintains "H" at
overcharge status. Each of the RSTO pin, the CLKO pin, and the CAO pin outputs a signal in 1.0 ms typ. from inputting.
When performing a self-test operation, input "L" to the RSTI pin. Refer to " Self-test Function" for the self-test
operation.
I/O
Input
Symbol
RSTI
CTL
CLKI
CAI
CO
Output RSTO
CLKO
CAO
Table 6
Normal Operation
"H"
"H"
"L"
"H"
"L"
"H"
"L"
"H" "L" "H" "L" "H" "L" "H" "L"
"H"
"L" (Normal status) /
"H" (Overcharge status)
"H"
"H"
"L"
Self-test Operation
"L"
"H"
"L"
"H"
"L"
"H"
"L"
"H" "L" "H" "L" "H" "L" "H" "L"
"H"
"L" (Normal status) /
"H" (Overcharge status)
Refer to "2. RSTO pin" in " Self-test Function"
Refer to "3. CLKO pin"in" Self-test Function"
Refer to "4. CAO pin" in " Self-test Function"
11