TDA 6160-2X
eighth bit is always low. The first bit of the first or third data byte in the data part of the telegram
determines whether a divider ratio or control information will follow. In every case the first byte must
be followed by a byte of the same data type (or a stop condition). When the supply voltage is
applied, a power-on reset circuit prevents the PLL from pulling the SDA-line to low and thus blocking
the bus.
Logic Allocations
Address byte
Progr. divider byte 1
Progr. divider byte 2
Control information
Address byte 1
Address byte 2
0
1
0
0
0 MA1 MA0 R/W A
0
0 n10 n9 n8 n7 n6 n5 A
n4 n3 n2 n1 n0 0
0
0
A
1 5I Z2 Z1 Z0 T2 T1 T0 A
0
1
0
0
0
1
0
0
A = H44
0
1
0
0
0
1
1
0
A = H46
Chip address (CA)
pin 5 on:
Test Mode
T2, T1, T0 = 0, 0, 0
T2, T1, T0 = 1, 0, 0
T2, T1, T0 = 1, 1, 0
T2, T1, T0 = 1, 1, 1
T2, T1, T0 = 0, 1, 1
ground = address byte 1
VS or open = address byte 2
normal operation
pin 2
pin 2
pin 2
= fREF
= fCy
= tristate
pin 2
= high-impedance = pin 3 high-impedance
IF-Muting Circuits
Z2, Z1, Z0 = 0, 0, 0
Z2, Z1, Z0 = 0, 0, 1
Z2, Z1, Z0 = 0, 1, 0
Z2, Z1, Z0 = 0, 1, 1
Z2, Z1, Z0 = 1, 0, 0
Z2, Z1, Z0 = 1, 0, 1
Z2, Z1, Z0 = 1, 1, 0
Z2, Z1, Z0 = 1, 1, 1
normal operation
IF 3
IF 2
IF 1 = on; IF 2/IF 3 = off
IF 1
IF 1 = off; IF 2 = on; IF 3 = off
IF 3 = on; IF 1/IF 2 = off
IF 1, IF 2, IF 3 = off
= off (output 14 high-impedance)
= off (output 11 high-impedance)
= off (output 8 high-impedance)
Semiconductor Group
151