TLE 4905 L; TLE 4935 L;
TLE 4935-2 L; TLE 4945 L; TLE 4945-2L
Magnetic Characteristics
3.8 V ≤ VS ≤ 24 V
Parameter Symbol
Limit Values
Unit
TLE 4905
unipolar
TLE 4935 TLE 4935-2 TLE 4945 TLE 4945-2
bipolar
bipolar
bipolar
bipolar
latch
latch
latch
latch
min. max. min. max. min. max. min. max. min. max.
Junction Temperature Tj = – 40 ˚C
Turn-ON
induction BOP
Turn-OFF
7.5 19 10 20 15 27 – 6 10 – 3 6 mT
induction BRP
Hysteresis
5.5 17 – 20 – 10 – 27 – 15 – 10 6 – 6 3 mT
(BOP-BRP)
∆BHY
2
6.5 20 40 30 54 2
10 1
5
mT
Junction Temperature Tj = 25 ˚C
Turn-ON
induction BOP
Turn-OFF
7 18 10 18 14 26 – 6 10 – 3 6 mT
induction BRP
Hysteresis
5 16 –18 –10 – 26 – 14 – 10 6 – 6 3 mT
(BOP-BRP)
∆BHY
2
6
20 36 28 52 2 10 1 5
mT
Junction Temperature Tj = 85 ˚C
Turn-ON
induction BOP
Turn-OFF
6.5 17.5 9 18 13 26 – 6 10 – 3 6 mT
induction BRP
Hysteresis
4.5 15 – 18 – 9 – 26 – 13 – 10 6 – 6 3 mT
(BOP-BRP)
∆BHY
2
5.5 18 36 26 52 2
10 1
5
mT
Semiconductor Group
8