Electrical Characteristics (TA=25°)
Parameter
SSR
LED Forward Current for Switch Turn-on
LED Forward Current for Switch Turn-off
LED Forward Voltage
ON-Resistance
OFF-Resistance
Current Limit
Output Off-state Leakage Current
Symbol Min. Typ.
IFon
IFoff
VF
RON
ROFF
Ilimit
0.001
0.8
17
170
0.2
1.20
2.5
5000
210
0.1
Output Capacitance
Pins 15 to 18
Turn-on Time
55
10
Ton
1.0
Turn-off Time
Toff
0.1
Optocoupler
LED Forward Voltage
DC Current Transfer Ratio
Saturation Voltage
Dark Current Leakage
Trickle Current Leakage
SSR Characteristic Curves
VF
0.9
CTR
33
VCEsat
ICEO
ICEO
1.25
165
.07
Max.
0.5
1.45
33
270
200
1
0.8
0.2
1.5
0.5
500
1
Unit Test Condition
mA
IL=100 mA, t=10 ms
mA
VL=± 350 V
V
IF=1.5 mA
W
IF=1.5 mA,IL=± 50 mA
GΩ
IF=0 mA, VL=± 100 V
mA
IF=1.5 mA, t=5 ms
nA
IF=0 mA, VL=± 100 V
µA
IF=0 mA, VL=± 400 V
pF
IF=0 mA, VL=1 V
pF
IF=0 mA, VL=50 V
ms
IF=1.5 mA, IL=50 mA
ms
IF=5.0 mA, IL=50 mA
ms
IF=1.5 mA, IL=50 V
ms
IF=5.0 mA, IL=50 mA
V
IF=10 mA
%
IF=6.0 mA, VCE=0.5 V
V
IF=16.0 mA, IC=2 mA
nA
IF=0 mA, VCE=5 V
µA
IF=5 µA, VCE=5 V
Figure 1. SSR recommended operating conditions
100
3 mA
80
60
0.5 mA 1 mA 2 mA
40
20
0
-40 -20 0 20 40 60 80
Ambient Temperature in °C
Figure 3. SSR turn-on current versus temperature
2.5
2.0
1.5
1.0
0.5
20
40
60
80
Ambient temperature in °C
Figure 2. IF versus VF, typical
120
100
80
85°C
60
40
25°C
20
0
0.6 0.8 1.0 1.2 1.4 1.6 1.8
VF- Input LED forward Voltage
Figure 4. SSR current vs. voltage, typical
300
200
100
0
-100
-200
-300
-4
-2
0
2
4
Vs-s' SSR voltage drop in Volts
5–107