English
Language : 

3RU1136-4EB0 Datasheet, PDF (2/5 Pages) Siemens Semiconductor Group – 3RU11 for standard applications
© Siemens AG 2011
Overload Relays
SIRIUS 3RU1 Thermal Overload Relays
3RU11 for standard applications
■ Selection and ordering data
3RU11 thermal overload relays with screw terminals on the auxiliary current side for direct mounting1), CLASS 10
Features and technical specifications:
• Overload and phase failure protection
• Auxiliary contacts 1 NO + 1 NC
• Manual and automatic RESET
• Switch position indicator
• TEST function
• STOP button
• Integrated, sealable cover
Size of Rating
Current setting of Short-circuit DT Screw terminals
PU
PS*
con- for induction
tactor2) motor
rated value3)
the inverse-time protection
delayed overload with fuse,
release
type of coor-
(on auxiliary current
side)
(UNIT,
SET, M)
dination 2,
gL/gG opera-
tional class4)
Order No.
Price
per PU
PG Weight
per PU
approx.
kW
A
A
kg
Size S00
S00 0.04
0.06
0.06
0.09
0.11 ... 0.16
0.5
0.14 ... 0.2
1
0.18 ... 0.25
1
0.22 ... 0.32
1.6
} 3RU11 16-0AB0
} 3RU11 16-0BB0
} 3RU11 16-0CB0
} 3RU11 16-0DB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.150
101 0.150
101 0.150
101 0.150
0.09
0.28 ... 0.4
2
} 3RU11 16-0EB0
0.12
0.35 ... 0.5
2
} 3RU11 16-0FB0
0.18
0.45 ... 0.63
2
} 3RU11 16-0GB0
0.18
0.55 ... 0.8
4
} 3RU11 16-0HB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.150
101 0.150
101 0.150
101 0.150
3RU11 16-..B0
0.25
0.7 ... 1
4
} 3RU11 16-0JB0
0.37
0.9 ... 1.25
4
} 3RU11 16-0KB0
0.55
1.1 ... 1.6
6
} 3RU11 16-1AB0
0.75
1.4 ... 2
6
} 3RU11 16-1BB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.150
101 0.150
101 0.150
101 0.150
0.75
1.8 ... 2.5
10
} 3RU11 16-1CB0
1.1
2.2 ... 3.2
10
} 3RU11 16-1DB0
1.5
2.8 ... 4
16
} 3RU11 16-1EB0
1.5
3.5 ... 5
20
} 3RU11 16-1FB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.150
101 0.150
101 0.150
101 0.150
2.2
4.5 ... 6.3
20
} 3RU11 16-1GB0
3
5.5 ... 8
25
} 3RU11 16-1HB0
4
7 ... 10
35
} 3RU11 16-1JB0
5.5
9 ... 12
35
} 3RU11 16-1KB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.150
101 0.150
101 0.150
101 0.150
Size S0
S0 0.75
1.1
1.5
1.5
1.8 ... 2.5
10
2.2 ... 3.2
10
2.8 ... 4
16
3.5 ... 5
20
} 3RU11 26-1CB0
} 3RU11 26-1DB0
} 3RU11 26-1EB0
} 3RU11 26-1FB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.190
101 0.190
101 0.190
101 0.190
2.2
4.5 ... 6.3
20
} 3RU11 26-1GB0
3
5.5 ... 8
25
} 3RU11 26-1HB0
4
7 ... 10
35
} 3RU11 26-1JB0
5.5
9 ... 12.5
35
} 3RU11 26-1KB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.190
101 0.190
101 0.190
101 0.190
7.5
3RU11 26-..B0
7.5
11
11
11 ... 16
40
14 ... 20
50
17 ... 22
63
20 ... 25
63
} 3RU11 26-4AB0
} 3RU11 26-4BB0
} 3RU11 26-4CB0
} 3RU11 26-4DB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.190
101 0.190
101 0.190
101 0.190
Size S2
S2 3
4
5.5
5.5 ... 8
25
7 ... 10
35
9 ... 12.5
35
} 3RU11 36-1HB0
} 3RU11 36-1JB0
} 3RU11 36-1KB0
1 1 unit
1 1 unit
1 1 unit
101 0.320
101 0.320
101 0.320
7.5
11 ... 16
40
} 3RU11 36-4AB0
7.5
14 ... 20
50
} 3RU11 36-4BB0
11
18 ... 25
63
} 3RU11 36-4DB0
15
22 ... 32
80
} 3RU11 36-4EB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.320
101 0.320
101 0.320
101 0.320
3RU11 36-..B0
18.5
28 ... 40
80
} 3RU11 36-4FB0
22
36 ... 45
100
} 3RU11 36-4GB0
22
40 ... 50
100
} 3RU11 36-4HB0
1 1 unit
1 1 unit
1 1 unit
101 0.320
101 0.320
101 0.320
Size S3
S3 11
15
18 ... 25
63
22 ... 32
80
} 3RU11 46-4DB0
} 3RU11 46-4EB0
1 1 unit
1 1 unit
101 0.550
101 0.550
18.5
28 ... 40
80
} 3RU11 46-4FB0
22
36 ... 50
125
} 3RU11 46-4HB0
30
45 ... 63
125
} 3RU11 46-4JB0
37
57 ... 75
160
} 3RU11 46-4KB0
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.550
101 0.550
101 0.550
101 0.550
45
45
3RU11 46-..B0
70 ... 90
160
80 ... 1005)
200
} 3RU11 46-4LB0
} 3RU11 46-4MB0
1 1 unit
1 1 unit
101 0.550
101 0.550
1) With the suitable terminal brackets (see "Accessories", page 5/50), the
3RU11 overload relays for direct mounting can also be installed as stand-
alone units.
2) Observe maximum rated operational current of the devices.
3) Guide value for 4-pole standard motors at AC 50 Hz 400 V. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
4) Maximum protection by fuse for overload relay, type of coordination 2.
For fuse values in conjunction with contactors, see "Technical
specifications" --> "Short-circuit protection with fuses/motor starter pro-
tectors for motor feeders", see note on Technical Information on page 5/1.
5) For overload relays > 100 A, see 3RB2.
* You can order this quantity or a multiple thereof.
Siemens LV 1 AO · 2011
5/47