English
Language : 

TDA4700 Datasheet, PDF (15/21 Pages) Siemens Semiconductor Group – Control IC for Single-Ended and Push-Pull Switched-Mode Power Supplies SMPS
TDA 4700
TDA 4718
Characteristics (cont’d)
VS = 11 to 30 V; TA = – 25 to 85 °C
Parameter
Symbol
Limit Values
min.
typ. max.
Unit Test
Condition
Symmetry (TDA 4700; TDA 4700 A)
Input voltage
Input current
VI H
2.0
VI L
– II
Output Stages Q1, Q2
V
0.8
V
2
µA
Output voltage
VQ H
VQ L
Output leakage
current
IQ
ON, OFF, Undervoltage K6
30
V
1.1
V
IQ = 20 mA
2
µA VQ H = 30 V
Switching voltage
Input current
Turn-OFF delay time1)
Error detection time1)
V
– II
tD OFF
t
VREF – 0.03
250
50
VREF + 0.03 V
2
µA
ns
ns
Dynamic Current Limitation K7
Common-mode input
voltage range
VIC
0
4
V
Input offset voltage VIO
– 10
10
mV
Input current
– II
2
µA
Turn-OFF delay time2) tD OFF
250
ns
Error detection time2) t
50
ns
Overvoltage K5
Switching voltage
Input current
Output current
Turn-OFF delay time1)
Error detection time1)
V
– II
– IQ
tD OFF
t
VREF – 0.03
0
250
50
VREF + 0.03 V
2
µA
200
µA
ns
ns
VQH min = 5 V
1) At the input: step function ∆V = VREF – 100 mV VREF + 100 mV
2) At the input: step function ∆V = – 100 mV ∆V = + 100 mV
Semiconductor Group
15