English
Language : 

BTS621L1 Datasheet, PDF (12/14 Pages) Siemens Semiconductor Group – Smart Two Channel Highside Power Switch (Overload protection Current limitation Short circuit protection Thermal shutdown)
Figure 4a: Overtemperature:
Reset if Tj <Tjt
IN
ST
BTS 621 L1
Figure 5b: Open load: detection in ON-state, turn
on/off to open load
IN1
IN2 channel 2: normal operation
V
OUT1
V
OUT
I
L1
channel 1: open load
T
t
d(ST)
t
d(ST OL4)
t
d(ST)
t
d(ST OL5)
J
ST
t
t
Figure 5a: Open load: detection in ON-state, open
load occurs in on-state
IN1
IN2 channel 2: normal operation
VOUT1
Figure 5c: Open load: detection in ON- and OFF-state
(with REXT), turn on/off to open load
IN1
IN2 channel 2: normal operation
V
OUT1
IL1
channel 1:
open
load
normal
load
open
load
t d(ST OL1) t d(ST OL2)
ST
t d(ST OL1)
t d(ST OL2)
t
td(ST OL1) = 30 µs typ., td(ST OL2) = 20 µs typ
I L1
channel 1: open load
ST
t d(ST)
t
d(ST)
t d(ST OL5)
t
td(ST OL5) depends on external circuitry because of high
impedance
Semiconductor Group
12