English
Language : 

LH1521 Datasheet, PDF (1/13 Pages) List of Unclassifed Manufacturers – HIGH VOLATAGE, PHOTO MOS RELAY
LH1521, LH1523
Dual 1 Form B
Absolute Maximum Ratings TA=25°C
Stresses in excess of the Absolute Maximum Ratings
can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the
device is not implied at these or any other conditions in
excess of those given in the operational sections of this
document. Exposure to Absolute Maximum Ratings for
extended periods of time can adversely affect reliability.
Parameter
Symbol Test Conditions
Ambient Operating Temperature Range
Storage Temperature Range
Pin Soldering Temperature
Input/Output Isolation Test Voltage
Pole-to-Pole Isolation Voltage*
(S1 to S2)
TA
—
Tstg
—
TS t=10 s max
VISO
Vrms t=1 s
IISO=10 µA max
— Dry air, dust free, at
sea level
LED Continuous Forward Current
LED Reverse Voltage
dc or Peak ac Load Voltage
Continuous dc Load Current
One Pole Operating
Two Poles Operating
IF
—
VR IR ≤ 10 µA
VL IL ≤ 50 µA
IL
—
Peak Load Current
IP t=100 ms
(single shot)
Output Power Dissipation (continuous)
PDISS
—
* Breakdown occurs between the output pins external to the package.
LH1521
–40 to +85
–40 to +150
260
5300
1600
50
8
350
150
110
400
600
LH1523
–40 to +85
–40 to +150
260
5300
1600
50
8
200
200
140
600
600
Units
°C
°C
°C
Vrms
V
mA
V
V
mA
mA
mA
mW
Recommended Operating Conditions
110
100
IFOFF =
5 mA to 20 mA
80
60
IFOFF = 2 mA
IFOFF = 3 mA
40
IFOFF = 4 mA
20
LH1521
0
–40 –20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Both relays on with equal load currents. For a single relay operation,
refer to LH1501 Recommended Operating Conditions graph.
140
IFOFF = 5 mA
120
to 20 mA
100
80
IFOFF = 2 mA
60
IFOFF = 3 mA
IFOFF = 4 mA
40
20
LH1523
0
–40 –20
0
20
40
60
80
AMBIENT TEMPERATURE (°C)
Both relays on with equal load currents. For a single relay operation,
refer to LH1511 Recommended Operating Conditions graph.
6G–41