English
Language : 

C4P-EA09030A001200 Datasheet, PDF (9/10 Pages) SICK AG – SAFETY LIGHT CURTAINS
C4P-SA09030A001200, C4P-EA09030A001200 | deTec4 Prime
SAFETY LIGHT CURTAINS
If the protective field is clear and the UE10-3OS is in a fault-free de-energized position, the field indicator and the H2 lamp flash.
The system can be switched on. The system is enabled by pressing S1 (pushbutton is pressed and released). Outputs OSSD1 and
OSSD2 carry voltage, the UE10-3OS is switched on. When the protective field is interrupted, the OSSD1 and OSSD2 outputs switch
the UE10-3OS off.
Fault analysis
Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). The malfunction of the
UE10-3OS is detected. The shut-down function is retained. Manipulation (e.g., jamming) of the S1 pushbutton prevents the output
circuits from being enabled.
2017-08-21 16:38:06 | Online data sheet
S ubject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
9