English
Language : 

C4P-SA15010A001100 Datasheet, PDF (7/10 Pages) SICK AG – SAFETY LIGHT CURTAINS
C4P-SA15010A001100, C4P-EA15010A001100 | deTec4 Prime
SAFETY LIGHT CURTAINS
deTec4 Prime safety light curtain cascade to UE10-3OS safety relay
+24 V
s
1
n.c.
2
+24 V
3
n.c.
4
n.c.
5
In2
6
In1
7 0V
8 Com1
r
1
RES
2
+24 V
3
ADO
5
OSSD1
OSSD2 6
EDM 4
0V 7
Com1 8
3)
2)
B1 B3 Y1 13 23 33 41 1)
UE10-3OS
B2 B4 Y2 14 24 34 42
deTec4 Prime
0V
4) PELV
E132954/00/2015-04-07
① Output circuits. These contacts must be incorporated into the control such that the dangerous state is brought to an end if the output circuit is
open. For categories 4 and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation into the control (z path) is only
possible with a single-channel control and taking the risk analysis into account.
② Connection of the 5-pin extension connection of the host device to the 5-pin system connection of the guest device.
③ To indicate the status on both sides, the Com1 connections from the sender and receiver must be connected to each other in the control cabi-
net (optional).
④ SELV/PELV safety/protective extra-low voltage.
2017-08-21 16:38:06 | Online data sheet
S ubject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
7