M40E-70A105RA0 Datasheet, PDF (6/8 Pages) SICK AG – MULTIPLE LIGHT BEAM SAFETY DEVICES
M40S-70A105AA0, M40E-70A105RA0 | M4000 Area
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Length of the monitored area S
300 (11.81)
450 (17.72)
600 (23.62)
750 (29.53)
900 (35.43)
1,050 (41.34)
1,200 (47.24)
1,350 (53.15)
1,500 (59.06)
1,650 (64.96)
1,800 (70.87)
L1
387 (15.24)
537 (21.14)
687 (27.05)
837 (32.95)
987 (38.86)
1,137 (44.76)
1,287 (50.67)
1,437 (56.57)
1,587 (62.48)
1,737 (68.39)
1,887 (74.29)
L2
416 (16.38)
566 (22.28)
716 (28.19)
866 (34.09)
1,016 (40.00)
1,166 (45.91)
1,316 (51.81)
1,466 (57.72)
1,616 (63.62)
1,766 (69.53)
1,916 (75.43)
Connection diagram
M4000 Area connected to UE10-3OS safety relay
+24 V
+24 V
1
Test
3
n.c.
4
n.c.
5
+24 V
1
RES
5
EDM
6
EFia
9
n.c.
6
EFib
10
n.c.
7
OSSD1
3
n.c.
8
OSSD2
4
EFIa
9
n.c.
11
EFIb
10
ADO
7
n.c.
11
RR
8
GND
2
GND
2
FE
FE
FE
FE
H2
M4000S
Area
M4000R
Area
S1
B1 B3
Y1 13 23 33 41 1)
UE10-3OS
H3
B2 B4 Y2 14 24 34 42
0V
2) PELV
E119955/00/2014-07-29
Task
Connection of an M4000 Area multiple light beam safety device to a UE10-3OS safety relay.
Operating mode: with restart interlock and external device monitoring.
Operating characteristics
When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3
lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and
releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of
the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs.
If the optics are dirty, H2 indicator illuminates.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the
UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does
not enable the output current circuits.
Comments
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2) PELV in accordance with the requirements in
EN 60204-1 / 6.4
Take note of the operating instructions of the integrated devices. This applies particularly to the use of configurable functions.