English
Language : 

M40E-025003WB0 Datasheet, PDF (6/9 Pages) SICK AG – MULTIPLE LIGHT BEAM SAFETY DEVICES
M40S-025003EA0, M40E-025003WB0 | M4000 Advanced
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Connection diagram
M4000 Advanced with UE403 switching amplifier connected to UE10-3OS safety relay
+24 V
1 +24V
3 Test
4 n.c.
5 n.c.
n.c.
6
n.c.
7
8 n.c.
9 EFIa
10 EFIb
11 n.c.
GND
2
FE
FE
M4000S
Advanced
+24V 1
RES 5
EDM 6
EFia 9
EFib
10
OSSD1
3
OSSD2 4
BS/C1 11
ADO 7
RR
8
GND
2
FE FE
5
COM
M4000R
Advanced
A1
A2
S2
S1
H3
+ -Q
+ -Q
5
B1 B3 Y1 13 23 33 41 1)
12345
+ RR - IN IN
RES/OVR
COM
L-
12345
12345
+ T - IN
A1
UE403
B2
+ T - IN
12345
12345
+ T - IN
A2
B1
+ T - IN
12345
H1
B2
Q
B1
Q
UE10-3OS
B2 B4 Y2 14 24 34 42
0V
2) PELV
E119906/00/2014-07-29
Task
Connection of an M4000 Advanced multiple light beam safety device with UE403 switching amplifier to a UE10-3OS safety relay.
Muting with 4 photoelectric reflex switches (dark-switching, PNP).
Operating mode: with restart interlock and external device monitoring.
Operating characteristics
When the light path is clear and the UE10-3OS is de-energized and functioning correctly, the yellow LED on the receiver and the H3
lamp flash. The system is ready for switch-on and waits for an input signal/switch-on signal. The system is enabled by pressing and
releasing the S1 button. The OSSD1 and OSSD2 outputs are live, the UE10-3OS is switched on. On interruption of one or several of
the light beams, the UE10-3OS is de-energized by the OSSD1 and OSSD2 outputs.
Muting and override
When the light path is clear and the muting input conditions are valid, muting starts. The H1 muting lamp illuminates. Different
time and monitoring functions can be configured.
When the light path is interrupted and muting sensors are active, e.g., because of muting errors or a new power on, override is en-
abled by pressing and releasing the S2 button.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The erroneous behavior of the
UE10-3OS will be detected. The shutdown function is retained. On manipulation (e.g., jamming) of the S1 button, the system does
not enable the output current circuits.
The failure of one muting sensor will be detected by the muting sequence and prohibit a new muting cycle. On manipulation (e.g.,
jamming) of the S2 button, the system does not enable override. A permanent use of the override function will be inhibited through
the device.
Comments
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2) PELV in accordance with the requirements in
EN 60204-1 / 6.4
Take note of the operating instructions of the integrated devices. This applies particularly to the use of configurable functions.
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-08-24 18:11:25
Subject to change without notice