MLG2-0880F812 Datasheet, PDF (5/7 Pages) SICK AG – MEASURING AUTOMATION LIGHT GRIDS | |||
|
◁ |
Adjustments
LED indicator
NC
15
26
7
38
49
blinks with 3 Hz
on
out
on or out
â Supply voltage
â¡ Device error
⢠No object in the light path
⣠Contamination control
⤠Blocked Beams Hold (BBH)
⥠Activated teach-in procedure
⦠ParamMode is active
⧠Standby
⨠Error: E1 = sync. error; E2 = less receiver signal; E9 = defect
Connection type and diagram
MLG2-0880F812 | MLG
MEASURING AUTOMATION LIGHT GRIDS
Sender
wht 1 Sync B
brn 2 L+
grn 3 Sync A
yel 4 nc 1
gra 5 TEST
pnk 6 nc 1
blu 7 M
red 8 nc 1
â Not assigned
Receiver
wht 1 Sync B
brn 2 L+
grn 3 Sync A
yel 4 In1/Teach-in
gra 5 Q1
pnk 6 Q2/RS-485 A
blu 7 M
red 8 Q3/RS-485 B
2016-01-29 09:44:08 | Online data sheet
S ubject to change without notice
AUTOMATION LIGHT GRIDS | SICK
5
|
▷ |