English
Language : 

DT50-2B215252 Datasheet, PDF (5/9 Pages) SICK AG – MID RANGE DISTANCE SENSORS
Connection diagram
brn 1 L+
wht 2 QA/Q2/¯ Q1/–
blu 3 M
blk 4 Q1/C
gra 5 MF 1
① Multifunctional input (MF)
Repeatability
DT50-2 Pro
Super Slow
Typ. repeatabilty in mm (inch)
10
(0.39)
8
(0.31)
Functional reserve
Secured performance
6
(0.24)
Specification basis
4 technical data
(0.16)
6 % Remission
18 % Remission
2
(0.08)
0.5
(0.02)
0.2
(0.66)
5
(16.40)
10
(32.81)
15
(49.21)
90 % Remission
20
25
30
(65.62) (82.02) (98.43)
Distance in m (feet)
DT50-2B215252 | Dx50-2
MID RANGE DISTANCE SENSORS
2016-03-19 03:03:08 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
5