English
Language : 

SEK37-HFA0-K02 Datasheet, PDF (4/7 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE
SEK37-HFA0-K02 | SEK/SEL37
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®
A
Axial
B
Proposed fitting
General tolerances according to DIN ISO 2768-mk
C
nominal position
D
E
minimum depth
center flange 1.7 (0.07)
3.4
(0.13)
2
(0.08)
F
Rz 6.3
(0.25)
0.02 A
1:3
H
I
J
K
L
M
N
O
P
Q
R
S
T
A
Axial
10
(0.39)
13
(0.51)
0.2±0.05
(0.01) x 45°
0.4
(0.02)
7.4+0.2
(0.29)
PIN assignment
View of the plug-in face
All dimensions in mm (inch)
PIN
Signal
Colour of wires (cable outlet)
Explanation
1
US
Red
Supply voltage
2
+ SIN
White
Process data channel
3
REFSIN
Brown
Process data channel
4
+ COS
Pink
Process data channel
5
REFCOS
Black
Process data channel
6
GND
Blue
Ground connection
7
Data +
Gray or yellow
Parameter channel RS 485
8
Data -
Green or purple
Parameter channel RS 485
The GND (0 V) connection of the supply voltage has no connection to the housing
4
MOTOR FEEDBACK SYSTEMS | SICK
Online data sheet | 2017-05-10 11:53:11
Subject to change without notice