English
Language : 

UM30-211113 Datasheet, PDF (3/7 Pages) SICK AG – ULTRASONIC SENSORS
UM30-211113 | UM30
ULTRASONIC SENSORS
Mechanics/electronics
Supply voltage Vs
Power consumption
Initialization time
Design
Housing material
Connection type
Indication
Weight
Sending axis
DC 9 V ... 30 V 1) 2)
≤ 2.4 W 3)
< 300 ms
Cylindrical
Nickel-plated brass, PBT
Display: TPU
Ultrasonic transducer: polyurethane foam, glass epoxy resin
Male connector, M12, 5-pin
LED display, 2 x LED
150 g
Straight
1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
2) 15 V ... 30 V when using the analog voltage output.
3) Without load.
Ambient data
Enclosure rating
Protection class
Ambient temperature
IP 67
III
Operation: –25 °C ... +70 °C
Storage: –40 °C ... +85 °C
Dimensional drawing (Dimensions in mm (inch))
UM30-211, UM30-212, UM30-213
11 (0.43)
84 (3.31)
51 (2.01)
33
1
2
5
(0.20)
① Connection
② Display
③ Mounting nuts, SW 36 mm
Connection type
Male connector M12, 5-pin
5
(0.20)
2016-05-02 22:08:07 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3