English
Language : 

PAC50-DGD Datasheet, PDF (3/6 Pages) SICK AG – PRESSURE SENSORS
PAC50-DGD | PAC50
PRESSURE SENSORS
Mechanics/electronics
Process connection
Housing material
Supply voltage
Power consumption
Electrical safety
CE-conformity
Weight sensor
Enclosure rating
Protection class III
RoHS certificate
CRUus certificate
2 x G ¼ 1)
Housing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR
17 V DC ... 30 V DC
Max. 40 mA at L+ = 24 VDC
Protection class: III
Overvoltage protection: 32 V DC
Short-circuit protection: QA, Q1, Q2 towards M and L+
Reverse polarity protection: L+ to M
EMC directive: 2004/108/EC, EN 61326-2-3
Approx. 40 g
IP 65 / IP 67 (according to IEC 60529) 2)
✔
✔
✔
1) Bottom side: thread G ¼ female, back side: thread G ¼ female, both according to DIN ISO 1630.
2) When plugged in with a suitable mating connector.
Ambient data
Ambient temperature
Storage temperature
Relative humidity
Shock load
Vibration load
0 °C ... +60 °C
–20 °C ... +80 °C
≤ 90 %
Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
Max. 5 g (10 ... 150 Hz), xyz, to DIN EN 60068-2-6
Dimensional drawing (Dimensions in mm (inch))
Bottom side: thread G ¼ female, back side: thread G ¼ female
M12x1
13.6
(0.54)
9.5
(0.37)
35
(1.38)
G1/4
2016-03-19 00:51:29 | Online data sheet
S ubject to change without notice
FLUID SENSORS | SICK
3