English
Language : 

OD2-P50W10I0 Datasheet, PDF (3/7 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
OD2-P50W10I0 | OD Value
DISPLACEMENT MEASUREMENT SENSORS
Mechanics/electronics
Supply voltage Vs
Power consumption
Warm-up time
Housing material
Connection type
Indication
Weight
DC 12 V ... 24 V 1)
≤ 2.88 W 2)
≤ 30 min
PBT housing with PMMA lens
Male connector, M12, 8-pin
Distance bar graph, up to 8 status LEDs
70 g
1) DC 12 V (-5 %) ... 24 V (+10 %); DC 18 V (-5 %) ... DC 24 V (+10 %) when using analog voltage output.
2) Without load, with current output.
Ambient data
Enclosure rating
Protection class
Ambient temperature
Relative air humidity (non-condensing)
Temperature drift
Typ. Ambient light immunity
Vibration resistance
Shock resistance
IP 67
III
Operation: –10 °C ... +40 °C
Storage: –20 °C ... +60 °C
35 % ... 95 %
± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx
10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
50 G (x, y, z axis 3 times each)
Dimensional drawing (Dimensions in mm (inch))
OD2-x50W10xx
50 (1.97)
42.4 (1.67)
3.8 (0.15)
2
1
Ø 5.5
(0.22)
2 Ø 4.5 (0.18)
① 2 m cable or M12 connector; 90° rotatable
② Mounting hole, Ø 4.5 mm
③ Optical axis sender
④ Optical axis receiver
1
16.1
(0.63)
20.4
(0.80)
3
4
2016-03-17 13:18:11 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3