English
Language : 

OD1-B015H05I25 Datasheet, PDF (3/7 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
Mechanics/electronics
Supply voltage Vs
Power consumption
Warm-up time
Housing material
Connection type
Indication
Operating elements
Weight
Dimensions
1) Without load, with current output.
Ambient data
Enclosure rating
Protection class
Ambient temperature
Min. rel. humidity (not condensing)
Max. rel. humidity (not condensing)
Temperature drift
Typ. Ambient light immunity
Vibration resistance
Shock resistance
General notes
Note
OD1-B015H05I25 | OD Mini
DISPLACEMENT MEASUREMENT SENSORS
DC 12 V (–5 %) ... DC 24 V (+10 %)
≤ 1.92 W 1)
≤ 5 min
Stainless steel housing with PPSU lens
Cable with male connector, M12, 5-pin, 30 cm
4-digit 7-segment display (plus 4 LEDs for status display)
4 buttons
70 g
44.4 mm x 31 mm x 17 mm
IP 67
III
Operation: –10 °C ... +40 °C
Storage: –20 °C ... +60 °C
35 %
95 %
± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx
10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
50 G (x, y, z axis 3 times each)
Not free of paint wetting impairment substances.
Dimensional drawing (Dimensions in mm (inch))
Stainless steel housing
2 x M3
31 (1.22)
3
(0.12)
17
(0.67)
2 1.1
(0.04)
1
Ø 4(0..518)
16
(0.63)
① Variant with 30 cm cable with M12, 5-pin connector
② Optical axis
2016-03-17 13:18:11 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3