Power consumption sender
Power consumption receiver
Ripple
Output current Imax.
Output load capacitive
Output load inductive
Initialization time
Dimensions (W x H x D)
Housing material
Indication
Synchronization
Enclosure rating
Circuit protection
Weight
Front screen
1) Without load.
2) Without load with 24 V.
3) Typical value.
Ambient data
Protection class
EMC
Ambient temperature
Ambient light immunity
Vibration resistance
Shock load
1) Sunlight.
MLG3-0120F521 | MLG
MEASURING AUTOMATION LIGHT GRIDS
≥ 150 mA 2)
≥ 115 mA 2)
< 5 Vpp
≤ 100 mA 3)
100 nF
1H
1s
34 mm x 214 mm x 29 mm
Aluminum
7-segment display, 7-segment display
Cable
IP 65
UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse
suppression
≥ 0.776 kg
PMMA
III
EN 60947-5-2
Operation: –25 °C ... +55 °C
Storage: –40 °C ... +70 °C
Direct: 12,500 lx 1)
Indirect: 50,000 lx 1)
5 g, 10 Hz ... 55 Hz (IEC 68-2-6)
10 g / IEC 68-2-29 / 16 ms