English
Language : 

M20E-061A3A122 Datasheet, PDF (3/7 Pages) SICK AG – MULTIPLE LIGHT BEAM SAFETY DEVICES
M20S-061A3A122, M20E-061A3A122 | M2000 Standard
MULTIPLE LIGHT BEAM SAFETY DEVICES
Interfaces
System connection
Connection type Male connector M12, 8-pin
Permitted cable length ≤ 15 m 1)
Permitted cross-section ≥ 0.25 mm²
Configuration method
Hard wired
Display elements
LEDs
7-segment display
Fieldbus, industrial network
Integration via Flexi Soft safety controller CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 2)
1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.
2) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
Electrical data
Protection class
Supply voltage VS
Power consumption
Safety outputs (OSSD)
Sender
III (EN 50178)
24 V DC (19.2 V DC ... 28.8 V DC) 1)
≤ 3.7 W (DC)
Type of output
Switching voltage HIGH
Switching voltage LOW
Switching current
Receiver
≤ 5 W (DC)
2 PNP semiconductors, short-circuit protect-
ed, cross-circuit monitored 2)
24 V DC (VS – 2.25 V DC ... VS)
≤ 1 V DC
≤ 500 mA
1) The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as
accessories from SICK.
2) Applies to the voltage range between –30 V and +30 V.
Mechanical data
Housing cross-section
Ambient data
48 mm x 40 mm
Enclosure rating
Ambient operating temperature
Storage temperature
Air humidity
Vibration resistance
Shock resistance
Other information
IP65 (EN 60529)
0 °C ... +55 °C
–25 °C ... +70 °C
15 % ... 95 %, Non-condensing
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
10 g, 16 ms (IEC 60068-2-29)
Wave length
950 nm
2017-06-14 08:06:28 | Online data sheet
S ubject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3