English
Language : 

DT500-A323 Datasheet, PDF (3/7 Pages) SICK AG – LONG RANGE DISTANCE SENSORS
Ambient data
Enclosure rating
Protection class
Electromagnetic compatibility (EMC)
Ambient temperature
Temperature drift
Mechanical load
1) Reference voltage DC 32 V.
DT500-A323 | Dx500
LONG RANGE DISTANCE SENSORS
IP 65
II 1)
EN 61000-6-2, EN 55011
EN 60947-5-7: 2003-9
Operation: –10 °C ... +45 °C
Operation with cooling case: –10 °C ... +75 °C
Storage: –25 °C ... +75 °C
Typ. 0.05 mm/K
Shock: EN 600 68-2-27 / –2-29
Sine: EN 600 68-2-6
Noise: EN 600 68-2-64
Dimensional drawing (Dimensions in mm (inch))
69 (2.72)
1
2
26
(1.02)
110 (4.33)
approx.
20
(0.79)
3
153 (6.02)
4
15
(0.59)
146 (5.75)
105 (4.13)
① Optical axis, sender
② Optical axis, receiver
③ Male connector M12, 5-pin
④ Zero level
⑤ Fixing hole
49 (1.93)
104 (4.09)
Connection type
DT500-Axx3 CAN (Layer 2) Connector M12, 8-pin
5
Ø9
(0.35)
2016-05-02 22:08:07 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3