DT50-2B215552 Datasheet, PDF (3/9 Pages) SICK AG – MID RANGE DISTANCE SENSORS
DT50-2B215552 | Dx50-2
MID RANGE DISTANCE SENSORS
Laser service life (MTTF at 25 °C)
100,000 h
1) For speed setting Slow.
2) See characteristic curves repeatability.
3) Equivalent to 1 σ.
4) 6 % ... 90 % remission.
5) Depending on the set speed: Super Fast ... Super Slow.
6) Lateral entry of the object into the measuring range.
7) Continuous change of distance in measuring range.
8) Wavelength: 658 nm; max. output: 250 mW; pulse duration: 3 ns; duty cycle: 1/666.
Interfaces
Analog output
1 x 4 mA ... 20 mA (≤ 450 Ω) / 1 x 0 V ... 10 V (≥ 50 kΩ) / – 1)
Resolution analog output
16 bit
Switching output
1 x / 2 x complementary / 2 x push-pull: PNP/NPN (100 mA), IO-Link 2) 3) 1)
Multifunctional input (MF)
1 x 4)
Hysteresis
0 mm ... 29,950 mm
Data interface
IO-Link
IO-Link
✔
Function Process data, parameterization, diagnosis, data storage
Data transmission rate 230.4 kbit/s
Protocol V1.1
1) Output Q2, adaptable: 4 mA ... 20 mA/0 V ... 10 V/switching output/Q1 not/deactivated.
2) Output Q short-circuit protected.
3) Voltage drop < 3 V.
4) Response time ≤ 60 ms.
Mechanics/electronics
Supply voltage Vs
DC 10 V ... 30 V 1) 2)
Ripple
≤ 5 Vpp 3)
Power consumption
≤ 1.7 W 4) 5)
Initialization time
≤ 300 ms
Warm-up time
≤ 15 min
Housing material
Die-cast zinc
Acrylic glass (PMMA)
Connection type
Male connector, M12, 5-pin
Indication
3 x LED, LC display
Weight
235 g
1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
2) When using IO-Link output Vs > 18 V. When using analog output Vs > 13 V.
3) May not fall short of or exceed VS tolerances.
4) At ≥ 0°C.
5) Without load.
Ambient data
Enclosure rating
IP 65, IP 67
Protection class
III
1) Uv ≤ 24 V.
2016-03-19 03:03:08 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK