English
Language : 

DME4000-114 Datasheet, PDF (3/7 Pages) SICK AG – LONG RANGE DISTANCE SENSORS
DME4000-114 | DME4000
LONG RANGE DISTANCE SENSORS
Ripple
Initialization time
Connection type
Indication
Weight
Output current IA
Current consumption
< 5 Vpp 1)
1.5 s 2)
Male connector, 1 x M12, 4-pin, 1 x M16, 8-pin
Display
Approx. 1,650 g
≤ 100 mA 3)
At 24 V DC < 250 mA
1) May not fall short of or exceed VS tolerances.
2) After loss of reflector < 1 s at max. speed Vmax < 1 m/s.
3) Short-circuit protected, overload-protected. Max. 100 nF / 20 mH.
Ambient data
Enclosure rating
Protection class
Electromagnetic compatibility (EMC)
Ambient temperature
Effect of air pressure
Effect of air temperature
Temperature drift
Mechanical load
IP 65
II 1)
EN 61000-6-2, EN 55011: Class B
Operation: –10 °C ... +55 °C
Operation with cooling case: –10 °C ... +75 °C
Storage: –25 °C ... +75 °C
0.3 ppm/hPa
1 ppm/K
Typ. 0.1 mm/K
Shock: (EN 600 68-2-27 / –2-29)
Sine: (EN 600 68-2-6)
Noise: (EN 600 68-2-64)
1) Reference voltage DC 32 V.
Dimensional drawing (Dimensions in mm (inch))
DME4000-xx4 DeviceNet
26
1
(1.02)
2
166 (6.54)
176 (6.93)
① LC display
② Center of optical axis
78
(3.07)
40
(1.57)
2016-03-17 13:18:11 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3