CLV412-2010 | CLV41x
BAR CODE SCANNERS
Mechanics/electronics
Electrical connection
Operating voltage
Power consumption
Housing
Housing color
Enclosure rating
Protection class
Weight
Dimensions (L x W x H)
1 x 15-pin D-Sub HD male connector (0.9 m)
5 V DC ... 30 V DC 1)
3W
Die-cast zinc, does not contain paint wetting impairment substances
Light blue (RAL 5012)
IP 65 (DIN 40 050)
III (IEC 1010-1)
320 g, with connecting cable
72 mm x 62.7 mm x 35.2 mm
1) UL certified for use with a Class 2 mains supply unit (checked to UL 1310)
Ambient data
Electromagnetic compatibility (EMC)
Vibration resistance
Shock resistance
Ambient operating temperature
Storage temperature
Permissible relative humidity
Ambient light immunity
Bar code print contrast (PCS)
EN 61000-6-3 / EN 61000-6-2
IEC 68-2-6 Test FC
IEC 68-2-27 Test EA
0 °C ... +40 °C
–20 °C ... +70 °C
± 90 %, Non-condensing
2,000 lx, on bar code
≥ 60 %