English
Language : 

VFS60A-TDPK01024 Datasheet, PDF (2/8 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY INCREMENTAL
VFS60A-TDPK01024 | VFS60
MOTOR FEEDBACK SYSTEMS ROTARY INCREMENTAL
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
VFS60A-TDPK01024
Other models and accessories www.sick.com/VFS60
Part no.
1037729
Illustration may differ
Detailed technical data
Performance
Number of lines per revolution
Reference signal, number
Reference signal, position
Error limits
Measuring step deviation
Maximum initialisation time
1,024 1)
1
90° electric, logically gated with A and B
± 0.03°
± 0.01°
≤ 30 ms
1) Factory programmed number of lines : 1024, level of output signal: TTL.
Interfaces
Communication interface
TTL/HTL programmable
Electrical data
Supply voltage range
Operating power consumption (no load)
Maximum output frequency
Maximum load current
4.5 V ... 32 V
≤ 60 mA 1)
≤ 820 kHz
≤ 30 mA
1) Without load.
Mechanical data
Shaft version
Shaft material
Flange type / stator coupling
Dimensions
Weight
Moment of inertia of the rotor
Operating speed
Through hollow shaft
Metal
Standard
See dimensional drawing
0.2 kg
40 gcm²
9,000 min⁻¹ 1)
1) Self-warming 3.3 K/1,000 1/min, when applying note working temperature range.
2) The universal cable outlet is positioned in such a way, that it is possible to lay the cable in a radial or axial direction without kinking it.
2
MOTOR FEEDBACK SYSTEMS | SICK
Online data sheet | 2017-07-07 18:51:26
Subject to change without notice