English
Language : 

UP56-212114 Datasheet, PDF (2/6 Pages) SICK AG – LEVEL SENSORS
UP56-212114 | UP56
LEVEL SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
UP56-212114
Other models and accessories www.sick.com/UP56
Illustration may differ
Detailed technical data
Features
Medium
Measurement
Measuring range in tank
Measuring range immersion tube
Process pressure
Process temperature
Fluids
Switch, Continuous
85 mm ... 350 mm
85 mm ... 1,500 mm 1)
0 bar ... 6 bar, gauge pressure
–25 °C ... +70 °C
1) At 6 bar gauge.
Performance
Accuracy of sensor element
Repeatability
Resolution
Response time
≤ 2 % 1)
± 0.15 % 1)
≤ 0.18 mm
≤ 84 ms 2)
1) From the full scale value.
2) Recovery time 32 ms ... 180 ms according to EMC EN 60947-5-7.
Electronics
Supply voltage
Residual ripple
Power consumption
Electrical connection
Output signal
Hysteresis
Signal voltage HIGH
Time delay before availability
9 V DC ... 30 V DC, Switching output 1)
15 V DC ... 30 V DC, Analog output 1)
± 10 %
≤ 80 mA 2)
Round connector M12 x 1, 5-pin
2 x NPN
5 mm
Uv –3 V
≤ 300 ms
1) Reverse-polarity protected.
2) At 24 V DC without output load.
2
FLUID SENSORS | SICK
Part no.
6041665
Online data sheet | 2016-06-16 18:15:07
Subject to change without notice