TIM310-1030000S01 Datasheet, PDF (2/6 Pages) SICK AG – 2D LASER SCANNERS
TIM310-1030000S01 | TiM3xx
2D LASER SCANNERS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
TIM310-1030000S01
Other models and accessories www.sick.com/TiM3xx
Detailed technical data
Features
Field of application
Light source
Laser class
Aperture angle
Scanning frequency
Angular resolution
Operating range
Max. range with 10 % reflectivity
Performance
Indoor
Infrared (850 nm)
1, eye-safe (EN 60825-1 (2007-10))
270°
15 Hz
1°
0.05 m ... 4 m
2m
Response time
Detectable object shape
Systematic error
Statistical error
Integrated application
Number of field sets
Simultaneous evaluation cases
Typ. 134 ms
Almost any
± 40 mm 1)
± 30 mm 1)
Field evaluation
1 (2 fields)
1 (2 fields)
1) Typical value; actual value depends on environmental conditions.
Interfaces
USB
Switching inputs
Switching outputs
Delay time
Dwell time
Optical indicators
✔, micro USB
Function AUX, parameterization, Output of measurement data
0 (PNP)
2 (PNP, Additional 1 x “Device Ready”)
134 ms ... 30,000 ms (programmable)
67 ms ... 10,000 ms (programmable)
2 LEDs (ON, switching status)
2
DETECTION AND RANGING SOLUTIONS | SICK
Part no.
1056791
Online data sheet | 2016-03-19 03:20:07
Subject to change without notice