English
Language : 

THTS-1AB530506MZ Datasheet, PDF (2/7 Pages) SICK AG – TEMPERATURE SENSORS
THTS-1AB530506MZ | THTS
TEMPERATURE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
THTS-1AB530506MZ
Other models and accessories www.sick.com/THTS
Illustration may differ
Part no.
6047740
Detailed technical data
Features
Measuring range
Sensor element
Analog signal output and ohmic load RA
Performance
Accuracy of sensor element
Transmitter accuracy
Transmitter linearity
Response time
–50 °C +150 °C
Pt100, Pt1000 (for 4 mA ... 20 mA version)
4 mA ... 20 mA, 2-wire (RA ≤ (L+ – 10 V) / 0.023 A [Ohm])
Class A according to IEC 60751 1)
± 0,25 K
≤ ± 0.1 % of span
t50 ≤ 3,3 s
t90 ≤ 9,7 s 2)
1) Class B (measuring range –50 ° C ... –30 ° C).
2) Depending on sensor configuration, according to IEC 60751.
Mechanics/electronics
Process connection
Conical coupling (DIN 11851) DN 32 with union nut
Insertion length/diameter of probe
50 mm / 6 mm
Wetted parts
Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm
Pressure resistance
Max. 40 bar at room temperature
Housing material
Stainless steel (CrNi)
Electrical connection
Round connector M12 x 1, 4-pin, IP 67 and IP 69 1)
Supply voltage
10 V DC ... 35 V DC
Maximum current consumption
Ca. 30 mA
Electrical safety
Protection class: III, dielectric strength: 500 V AC, Reverse polarity protection: L+ to M
Protection class III
✔
CE-conformity
2004/108/EC, EN 61326-2-3
RoHS certificate
✔
Initialization time
Max. 4 s
1) IP enclosure rating as per IEC 60529. The enclosure rating classes specified only apply while the device is connected with male cable connectors of the correspond-
ing enclosure rating.
2
FLUID SENSORS | SICK
Online data sheet | 2017-03-14 16:25:09
Subject to change without notice