English
Language : 

THTL-1PAAB0213MZ Datasheet, PDF (2/6 Pages) SICK AG – TEMPERATURE SENSORS
THTL-1PAAB0213MZ | THTL
TEMPERATURE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
THTL-1PAAB0213MZ
Other models and accessories www.sick.com/THTL
Illustration may differ
Part no.
6047644
Detailed technical data
Features
Measuring range
Sensor element
Output signal
Performance
–50 °C +150 °C
Pt100, Pt1000 (for 4 mA ... 20 mA version)
Pt100, 4-wire
Accuracy of sensor element
Transmitter accuracy
Transmitter linearity
Response time
Class A according to IEC 60751 1)
± 0,25 K
≤ ± 0.1 % of span
t50 ≤ 3,2 s
t90 ≤ 9,1 s 2)
1) Class B (measuring range –50 ° C ... –30 ° C).
2) Depending on sensor configuration, according to IEC 60751.
Mechanics/electronics
Process connection
Nominal width
Wetted parts
Pressure resistance
Housing material
Electrical connection
Measuring current
Electrical safety
Protection class III
RoHS certificate
Initialization time
Angled pipe (DIN EN ISO 1127 and DIN 11866), row B, for welding
DN 21.3
Stainless steel 1.4435 / 316L, Ra ≤ 0.8 µm
Max. 25 bar at room temperature
Stainless steel (CrNi)
Round connector M12 x 1, 4-pin, IP 67 and IP 69 1)
0.1 mA ... 1 mA
Protection class: III, dielectric strength: 500 V AC
✔
✔
Max. 4 s
1) IP enclosure rating as per IEC 60529. The enclosure rating classes specified only apply while the device is connected with male cable connectors of the correspond-
ing enclosure rating.
2
FLUID SENSORS | SICK
Online data sheet | 2017-03-14 16:25:09
Subject to change without notice