English
Language : 

TCT-1PATE1006MZ Datasheet, PDF (2/5 Pages) SICK AG – TEMPERATURE SENSORS
TCT-1PATE1006MZ | TCT
TEMPERATURE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
TCT-1PATE1006MZ
Other models and accessories www.sick.com/TCT
Illustration may differ
Part no.
6043197
Detailed technical data
Features
Measuring range
Sensor element
Output signal
Performance
–50 °C +150 °C
Pt100
Pt100, 4-wire
Accuracy of sensor element
Transmitter accuracy
Transmitter linearity
Response time
Class A according to IEC 60751
≤ ± 1,0 % of span
≤ 0.1 % of span
Response time t50: ≤ 2.8 s 1)
t90 ≤ 9,1 s 1)
1) Depending on sensor configuration, according to IEC 60751.
Mechanics/electronics
Process connection
Insertion length/diameter of probe
Wetted parts
Pressure resistance
Housing material
Electrical connection
Measuring current
Supply voltage
Electrical safety
Protection class III
RoHS certificate
Weight
Initialization time
Thermowell G ½ B
100 mm / 6 mm
Stainless steel 1.4571
Max. 220 bar
Stainless steel 1.4571
Round connector M12 x 1, 4-pin, IP 67 1)
0.3 mA ... 1 mA
10 V DC ... 35 V DC
Protection class: III, dielectric strength: 500 V
✔
✔
Ca. 145 g (depending on configuration)
< 10 ms
1) IP enclosure rating as per IEC 60529. The enclosure rating classes specified only apply while the device is connected with male cable connectors of the correspond-
ing enclosure rating.
2
FLUID SENSORS | SICK
Online data sheet | 2017-02-23 11:18:08
Subject to change without notice