English
Language : 

TBT-1ABZZ1006GZ Datasheet, PDF (2/5 Pages) SICK AG – TEMPERATURE SENSORS
TBT-1ABZZ1006GZ | TBT
TEMPERATURE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
TBT-1ABZZ1006GZ
Other models and accessories www.sick.com/TBT
Illustration may differ
Part no.
6043129
Detailed technical data
Features
Measuring range
Sensor element
Analog signal output and ohmic load RA
Performance
Accuracy of sensor element
Transmitter accuracy
Transmitter linearity
Response time
–50 °C +250 °C
Pt100
4 mA ... 20 mA, 2-wire (RA ≤ (L+ – 10 V) / 0.028 A [Ohm])
Class A according to IEC 60751
≤ ± 0.1 % of span
≤ 0.1 % of span
Response time t50: ≤ 5.8 s 1)
Response time t90: ≤ 15.5 s 1)
1) Depending on sensor configuration, according to IEC 60751.
Mechanics/electronics
Process connection
Without process connection
Insertion length/diameter of probe
100 mm / 6 mm
Wetted parts
Stainless steel 1.4571
Housing material
Aluminum
Electrical connection
Cable gland M16 x 1.5, IP65 1)
Measuring current
0.3 mA ... 1 mA
Supply voltage
10 V DC ... 35 V DC
Maximum current consumption
Max. 28 mA
Electrical safety
Protection class: III, insulation voltage: 100 V, reverse polarity protection of variant with mea-
suring transducer 4 mA ... 20 mA: L+ to M
Protection class III
✔
CE-conformity
2004/108/EC, EN 61326-2-3
RoHS certificate
✔
Weight
Ca. 155 g (depending on configuration)
Initialization time
< 1 ms
1) IP enclosure rating as per IEC 60529. The enclosure rating classes specified only apply while the device is connected with male cable connectors of the correspond-
ing enclosure rating.
2
FLUID SENSORS | SICK
Online data sheet | 2017-02-23 11:18:08
Subject to change without notice