English
Language : 

S30B-2011DA Datasheet, PDF (2/9 Pages) SICK AG – SAFETY LASER SCANNERS
S30B-2011DA | S300 Professional
SAFETY LASER SCANNERS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
S30B-2011DA
The system plug has to be ordered separately. For details, see “Accessories”.
Other models and accessories www.sick.com/S300_Professional
system plug not supplied with delivery
Detailed technical data
Features
Protective field range
Warning field range
Distance measuring range
Type of field set
Number of field sets
Number of fields
Number of monitoring cases
Scanning angle
Resolution (can be configured)
Angular resolution
Response time
Protective field supplement
Number of multiple samplings
Delay of automatic reset
2m
8 m (at 15 % reflectivity)
30 m
Triple field sets
8
24
32 1)
270°
30 mm, 40 mm, 50 mm, 70 mm
0.5°
80 ms 2)
100 mm
2 ... 16, configurable
2 s ... 60 s, configurable
1) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise eight.
2) Depending on basic response time and multiple sampling.
Safety-related parameters
Type
Type 3 (IEC 61496)
Safety integrity level
SIL2 (IEC 61508)
SILCL2 (EN 62061)
Category
Category 3 (EN ISO 13849)
Performance level
PL d (EN ISO 13849)
PFHD (mean probability of a dangerous fail- 8.0 x 10-8 (EN ISO 13849)
ure per hour)
TM (mission time)
20 years (EN ISO 13849)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Part no.
1026822
Online data sheet | 2017-05-23 16:45:04
Subject to change without notice