English
Language : 

PAC50-FGC Datasheet, PDF (2/6 Pages) SICK AG – PRESSURE SENSORS
PAC50-FGC | PAC50
PRESSURE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
PAC50-FGC
Other models and accessories www.sick.com/PAC50
Part no.
1077857
Illustration may differ
Detailed technical data
Features
Medium
Pressure type
Measuring range
Process temperature
Analog signal output and ohmic load RA
Zero point adjustment
Output signal
Diagnostics output
Display
Initialization time
Performance
Non-linearity
Accuracy
Setting accuracy of switching outputs
Non-repeatability
Rated temperature range
Mechanics/electronics
Process connection
Housing material
Dry compressed air
Gauge pressure
–1 bar ... 10 bar
0 °C ... +60 °C
Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or
programmable. Output signals can be inverted: 20 mA ... 4 mA / 10 V ... 0 V
Load resistance for current output < 600 Ohm
Load resistance with current output > 3 kOhm
Max. + 5 % of span
2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V ... 10 V
Switching output 2 can be set as diagnostics output
LCD with LED backlight (green/red), can be rotated electronically by 180°
Pressure display: 4 digits, 16 segments
Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg
Update: 1,000, 500, 200, 100 ms (adjustable)
300 ms
≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
≤ ± 1.5 % of the span including non-linearity, hysteresis, zero point and full scale error (corre-
sponds to error of measurement as per IEC 61298-2)
≤ ± 0.2 % of span
≤ ± 0.2 % of the span
+10 °C ... +60 °C
2 x G ¼ 1)
Housing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR
1) Bottom side: thread G ¼ female, back side: thread G ¼ female, both according to DIN ISO 1630.
2) When plugged in with a suitable mating connector.
2
FLUID SENSORS | SICK
Online data sheet | 2016-03-19 00:51:29
Subject to change without notice