English
Language : 

OLM100-1201 Datasheet, PDF (2/6 Pages) SICK AG – LINEAR MEASUREMENT SENSORS
OLM100-1201 | OLM100 Hi
LINEAR MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
OLM100-1201
Other models and accessories www.sick.com/OLM100_Hi
Detailed technical data
Performance
Resolution
Repeatability
Output time
Light source
Measurement range
Max. movement speed
Sensing distance
Bar code width
0.1 mm, 1 mm
0.15 mm 1)
1 ms
LED, red
0 m ... 10,000 m 2)
10 m/s
100 mm, ± 20 mm
30 mm
1) Statistical error 3 σ.
2) Dependent on the set resolution and transfer protocol.
Interfaces
Data interface
SSI
Mechanics/electronics
Supply voltage Vs
Ripple
Power consumption
Initialization time
Housing material
Weight
DC 10 V ... 30 V 1)
≤ 5 Vpp
<3W
<3s
Magnesium
Zinc
Approx. 168 g
1) Limit values, reverse-polarity protected.
Ambient data
Enclosure rating
Protection class
IP 65 (EN 60 529)
III
1) Temperatures < –20 °C with 5 min warm up time.
2) Max. 95 % humidity, non-condensing.
3) Typ. value at +25 °C ambient temperature.
2
DISTANCE SENSORS | SICK
Part no.
1053074
Online data sheet | 2016-05-02 22:08:07
Subject to change without notice