English
Language : 

OD5-30T05 Datasheet, PDF (2/7 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
OD5-30T05 | OD Precision
DISPLACEMENT MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
OD5-30T05
Other models and accessories www.sick.com/OD_Precision
Part no.
6035977
Detailed technical data
Features
System part
Performance
Measuring range
Resolution
Repeatability
Linearity
Response time
Measuring frequency
Light source
Laser class
Typ. light spot size (distance)
Additional function
Note
Sensor head
25 mm ... 35 mm, 6 % ... 90 % remission; at default settings
0.2 µm 1)
0.6 µm 1)
± 8 µm 1)
0.1 ms 2) 3)
10 kHz 3)
Laser, red
2 (EN 60825-1) 4)
30 µm x 100 µm (30 mm)
Mean-value setting 1 … 4,096x, selectable measuring frequency (automatic / 0.1 ms ...
3.2 ms), automatic sensitivity adjustment, manual sensitivity adjustment, Mutual interference,
Glass thickness measurement
OD Precision sensor head can be used in combination with AOD5-P/N1 or stand-alone via
RS-422
1) Measurement at 90% remission (ceramic, white), or mirror for OD5-25x; averaging set to: 256 or 4096 for OD5-25x; constant ambient conditions.
2) Time needed for automatic sensitivity adjustment is calculated as: sampling period x 20. At default setting 100 µs (10kHz) this is <= 2ms.
3) Default setting for OD5-350x100 and OD5-500x200 = 0.8 ms, or 1.25 kHz, all others = 0.1 ms/10 kHz.
4) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
Laser-off input
1 x laser-off
Data interface
RS-422
Mechanics/electronics
Supply voltage Vs
Warm-up time
Housing material
Connection type
Indication
DC 12 V ... 24 V 1)
≤ 5 min
Aluminum housing with glass lens
0.5 m cable with connector 2)
LEDs, 4'' color display on optional evaluation unit
1) DC 12 V (–5 %) ... DC 24 V (+10 %)
2) Can be extended to up to 50 m with extension cable.
3) Includes 0.5 m cable.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice