English
Language : 

OD2-P50W10C0 Datasheet, PDF (2/7 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
OD2-P50W10C0 | OD Value
DISPLACEMENT MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
OD2-P50W10C0
Other models and accessories www.sick.com/OD_Value
Part no.
6036599
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Linearity
Response time
Measuring frequency
Light source
Laser class
Typ. light spot size (distance)
Additional function
40 mm ... 60 mm, 6 % ... 90 % remission
5 µm 1)
15 µm 2) 1) 3) 4)
± 20 µm 1) 5) 4) 6)
1 ms / 10 ms / 35 ms 7)
2 kHz
Laser, red
2 (EN 60825-1) 8)
0.5 mm x 1 mm (50 mm)
Mean-value setting 1 … 64x, automatic sensitivity adjustment, Teach-in of switching output, In-
vertable switching output, multifunctional input: laser-off / external teach-in / trigger, switching
mode: distance to object (DtO), switching mode: window (Wnd)
1) At averaging function medium.
2) 6 % ... 90 % remission.
3) Constant ambient conditions.
4) For best performance consider warm up time ≤ 5 minutes.
5) Measurement on 90 % remission (ceramic, white)
6) When calibrated in the application regularly.
7) Automatic sensitivity adjustment ≤ 4 ms, 6 ms for the models with measuring range of 100 mm ... 400 mm.
8) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
Switching output
Multifunctional input (MF)
2 x PNP (100 mA) 1)
1 x MF 2)
1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS.
2) MF can be used as laser-off, trigger, external teach-in, or deactivated; response time ≤ 3 ms.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice