English
Language : 

OD2-N250W150U2 Datasheet, PDF (2/7 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
OD2-N250W150U2 | OD Value
DISPLACEMENT MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
OD2-N250W150U2
Other models and accessories www.sick.com/OD_Value
Part no.
6036634
Detailed technical data
Performance
Measuring range
Resolution
Repeatability
Linearity
Response time
Measuring frequency
Light source
Laser class
Typ. light spot size (distance)
Additional function
100 mm ... 400 mm, 6 % ... 90 % remission
75 µm 1)
225 µm 2) 1) 3) 4)
± 750 µm 1) 5) 4) 6)
2 ms / 15 ms / 50 ms 7)
1.3 kHz
Laser, red
2 (EN 60825-1) 8)
1.8 mm x 3.5 mm (250 mm)
Mean-value setting 1 … 64x, automatic sensitivity adjustment, Analog outputs can be taught
in, Invertable analog output, Teach-in of switching output, Invertable switching output, multi-
functional input: laser-off / external teach-in / trigger, switching mode: distance to object (DtO),
switching mode: window (Wnd)
1) At averaging function medium.
2) 6 % ... 90 % remission.
3) Constant ambient conditions.
4) For best performance consider warm up time ≤ 5 minutes.
5) Measurement on 90 % remission (ceramic, white)
6) When calibrated in the application regularly.
7) Automatic sensitivity adjustment ≤ 4 ms, 6 ms for the models with measuring range of 100 mm ... 400 mm.
8) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
Switching output
Multifunctional input (MF)
Data interface
2 x NPN (100 mA) 1)
1 x MF 2)
1 x 0 V ... 10 V (> 10 kΩ)
1) PNP: HIGH = VS - (< 2 V) / LOW = < 2 V; NPN: HIGH = < 2 V / LOW = VS.
2) MF can be used as laser-off, trigger, external teach-in, or deactivated; response time ≤ 3 ms.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice