English
Language : 

MLG5-0250F51L Datasheet, PDF (2/6 Pages) SICK AG – MEASURING AUTOMATION LIGHT GRIDS
MLG5-0250F51L | MLG
MEASURING AUTOMATION LIGHT GRIDS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
MLG5-0250F51L
Other models and accessories www.sick.de/MLG
Detailed technical data
Features
Technology
Minimum detectable object (MDO)
Beam separation
Number of beams
Detection height
Configuration
Sender/receiver
Cross beam, 30 mm 1)
50 mm
≥6
250 mm
3-times cross beam and Q inv.
1) MDO min. detectable object.
Performance
Maximum range
Minimum range
Working range
Response time
7 m 1)
Cross beam: ≥ 840 mm
5m
Cross beam ≥ 5.7 ms 2)
1) No reserve for environmental issue and deterioration of the diode.
2) With resistive load.
Interfaces
Switching output
1 x PNP
Connection type
Male connector M12, 5-pin
Fieldbus, industrial network
-
Type of fieldbus integration
-
Mechanics/electronics
Wave length
Supply voltage Vs
Infrared light, 880 nm
DC 18 V ... 30 V 1)
1) Without load.
2) Without load with 24 V.
3) Typical value.
2
AUTOMATION LIGHT GRIDS | SICK
Part no.
1023622
Online data sheet | 2016-01-29 09:44:08
Subject to change without notice