MLG3-1470P811 Datasheet, PDF (2/8 Pages) SICK AG – MEASURING AUTOMATION LIGHT GRIDS
MLG3-1470P811 | MLG
MEASURING AUTOMATION LIGHT GRIDS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
MLG3-1470P811
Other models and accessories www.sick.de/MLG
Detailed technical data
Features
Technology
Minimum detectable object (MDO)
Beam separation
Number of beams
Detection height
Configuration
Sender/receiver
Parallel beam, 35 mm 1)
30 mm
≥ 50
1,470 mm
GSD data file
1) MDO min. detectable object.
Performance
Maximum range
Minimum range
Working range
Response time
7 m 1)
Parallel beam: ≥ 0 mm
5m
Parallel beam ≥ 8.5 ms 2)
1) No reserve for environmental issue and deterioration of the diode.
2) With resistive load.
Interfaces
Switching output
Inputs
Connection type
Data interface
Fieldbus, industrial network
Type of fieldbus integration
1 x PNP
1 x PNP
Male connector M12, 8-pin
PROFIBUS
PROFIBUS DP
Integrated in the device
2
AUTOMATION LIGHT GRIDS | SICK
Part no.
1042974
Online data sheet | 2016-01-29 09:44:08
Subject to change without notice