English
Language : 

MLG2-1940I822 Datasheet, PDF (2/7 Pages) SICK AG – MEASURING AUTOMATION LIGHT GRIDS
MLG2-1940I822 | MLG
MEASURING AUTOMATION LIGHT GRIDS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
MLG2-1940I822
Other models and accessories www.sick.de/MLG
Detailed technical data
Features
Technology
Minimum detectable object (MDO)
Beam separation
Number of beams
Detection height
Configuration
Sender/receiver
Parallel beam, 30 mm 1)
20 mm
≥ 98
1,940 mm
Parameterization interface (measuring)
1) MDO min. detectable object.
Performance
Maximum range
Minimum range
Working range
Response time
12 m 1)
Parallel beam: ≥ 0 mm
8.5 m
Parallel beam ≥ 15.7 ms 2)
1) No reserve for environmental issue and deterioration of the diode.
2) With resistive load.
Interfaces
Switching output
1 x PNP
Inputs
1 x PNP
Connection type
Male connector M12, 8-pin
Data interface
RS-485
Fieldbus, industrial network
-
Type of fieldbus integration
-
Mechanics/electronics
Wave length
Supply voltage Vs
Power consumption sender
Power consumption receiver
Ripple
Infrared light, 880 nm
DC 18 V ... 30 V 1)
≥ 336 mA 2)
≥ 394 mA 2)
< 5 Vpp
1) Without load.
2) Without load with 24 V.
3) Typical value.
2
AUTOMATION LIGHT GRIDS | SICK
Part no.
1024289
Online data sheet | 2016-01-29 09:44:08
Subject to change without notice