English
Language : 

M20E-03240A222 Datasheet, PDF (2/6 Pages) SICK AG – MULTIPLE LIGHT BEAM SAFETY DEVICES
M20S-03240A122, M20E-03240A222 | M2000 RES/EDM
MULTIPLE LIGHT BEAM SAFETY DEVICES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
System part
Sender
Receiver
Type
M20S-03240A122
M20E-03240A222
Part no.
1018178
1018209
1.) Concerns installation as a replacement part for previous type 2 device in machine: Regarding Machinery Directive
2006/42/EC, Article 1, Paragraph (2a) this type 2 device may only be used as a replacement part for identical PL d / SIL2
devices within the EU if the machine was put into circulation before 2015-05-10. Keep this note with your machine documen-
tation. If the machine is sold on, this note and the information it contains must be passed on to every subsequent buyer. 2.)
Concerns installation on new machines: Due to the amendment to the EN/IEC 61496-1 standard, this type 2 device may only
be installed on new machines up to PL c / SIL1 as of 2015-05-10.
Other models and accessories www.sick.com/M2000_RES_EDM
Detailed technical data
Safety-related parameters
Type
Type 2 (IEC 61496)
Safety integrity level
Category
SIL1 (IEC 61508)
SILCL1 (EN 62061)
Category 2 (EN ISO 13849)
Test rate (internal test)
Maximum demand rate
Performance level
13 /s (EN ISO 13849) 1)
≤ 8 min⁻¹ (EN ISO 13849) 2)
PL c (EN ISO 13849)
PFHD (mean probability of a dangerous fail- 6.6 x 10-9 (EN ISO 13849)
ure per hour)
TM (mission time)
Safe state in the event of a fault
20 years (EN ISO 13849)
At least one OSSD is in the OFF state.
1) Internal test. The test rate may not be exceeded if an external test is performed.
2) Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out.
Functions
Functions
Delivery status
Restart interlock
✔
Beam coding
✔
Uncoded
Configurable scanning range
✔
Interfaces
System connection
Connection type Male connector M12, 8-pin
Conductor cross-section 0.25 mm²
Permitted cable length ≤ 15 m 1)
Permitted cross-section ≥ 0.25 mm²
1) Depending on load, power supply and wire cross-section. The technical specifications must be observed.
2) For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-06-14 08:06:28
Subject to change without notice