English
Language : 

LFV310-XXGAVXPRX Datasheet, PDF (2/4 Pages) SICK AG – LEVEL SENSORS
LFV310-XXGAVXPRX | LFV300
LEVEL SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
LFV310-XXGAVXPRX
Other models and accessories www.sick.com/LFV300
Illustration may differ
Part no.
6043568
Detailed technical data
Features
Medium
Measurement
Probe length
Process pressure
Process temperature
Fill material density
GOST approval
Performance
Accuracy of sensor element
Repeatability
Viscosity
Response time
Electronics
Power consumption
Initialization time
VDE protection class 1
Electrical connection
Supply voltage
Hysteresis
Output current
Inductive load
Capacitive load
Contact load
Enclosure rating
Temperature drift
2
FLUID SENSORS | SICK
Fluids
Switch
66 mm
–1 bar ... 64 bar
–50 °C ... +150 °C
0.5 g/cm³ ... 2.5 g/cm³
✔
± 2 mm
≤ 1 mm
0.1 mPas ... 10,000 mPas
500 ms
5 mA ... 30 mA
<2s
✔
M20 x 1.5
Double relay (DPDT): 20 V DC ... 72 V DC / 20 V AC ... 253 V AC
2 mm
> 10 µA; < 3A AC, 1A DC
750 VA 54 W
750 VA 54 W
Min. 50 mW / max. 750 VA, 54 W
IP 66 / IP 67
0,03 mm/K
Online data sheet | 2016-05-11 15:58:08
Subject to change without notice