English
Language : 

LFH-SB1X6G1AS20SZ0 Datasheet, PDF (2/5 Pages) SICK AG – PRESSURE SENSORS
LFH-SB1X6G1AS20SZ0 | LFH
PRESSURE SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
LFH-SB1X6G1AS20SZ0
Other models and accessories www.sick.com/LFH
Illustration may differ
Part no.
6040955
Features
Medium
Pressure type
Measuring range
Process temperature
Output signal
Cable length
Fluids
Gauge pressure
0 bar ... 1.6 bar
–10 °C ... +50 °C
4 mA ... 20 mA, 2-wire
20 m
Performance
Non-linearity
Accuracy
Non-repeatability
Long-term drift/one-year stability
Temperature coefficient in rated tempera-
ture range
Rated temperature range
≤ ± 0.2 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
≤ ± 0.5 % of the span 1)
≤ ± 0.1 % of the span
≤ ± 0.2 % of span (at reference conditions)
Mean TC of zero: ≤ 0.2 % of span / 10 K (< 0.4 % for pressure ranges ≤ 0.25 bar), Mean TC of
span ≤ 0.2 % of span / 10 K
0 °C ... +50 °C
1) Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement as per IEC 61298-2).
Mechanics/electronics
Wetted parts
Electrical connection
Supply voltage
Electrical safety
Dielectric strength
CE-conformity
Weight sensor
Housing: Stainless steel
Pressure connection/diaphragm: CrNi steel
Protection cap: PA
PUR cable
10 V DC ... 30 V DC
14 V DC ... 30 V DC with output signal 0 V ... 10 V (only with enhanced varient)
Protection class: III
Short-circuit protection: QA towards M
Reverse polarity protection: L+ to M
Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced variant
500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even in the
event of a fault)
EMC directive: 2004/108/EC, EN 61 326-2-3
0.18 kg
2
FLUID SENSORS | SICK
Online data sheet | 2017-02-13 13:16:27
Subject to change without notice